Skip to Main Content
IBM Power Ideas Portal


This portal is to open public enhancement requests against IBM Power Systems products, including IBM i. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

FILTER BY CATEGORY

PowerVM VIOS

Showing 8

After VIOS complete boot to trigger any IBM i VMs to start

We could not find a mechanism to start IBM i VMs after VIOS complete IPL. This is necessary for unattended operations in case of power failure or a complete reboot of the hardware is required. VIOS starts automatically after the hardware is starte...
about 1 month ago in PowerVM VIOS 0 Submitted

The possibility of using LPM (Live Partition Mobility) between two Power10 servers connected in direct attached mode to an IBM FS5035 storage

Customer purchased a second power10 for this purpose, but the LPM does not work. IBM Support states that LPM in a direct attached environment (no San Switches) is not supported. Is it possible to find a solution?
about 2 months ago in PowerVM VIOS 0 Submitted

MVP for PowerVM VIOS

Today, IBM supply ISO images for the target PowerVM VIOS levels via entitled software distribution channel. However considering the overall security and audit posture for the clients ,can IBM look at providing a 'slimmer' VIOS image that only cont...
4 months ago in PowerVM VIOS 0 Submitted

Use syslog service on VIO to send syslog into to syslog-ng splunk server

In talking with our Premium Proactive Support Team Lead Kellie Kronenberger she encouraged us to submit what our security team is seeking to implement via syslog as regards certain VIO servers in our environment. What our security team wants to ha...
11 months ago in PowerVM VIOS 0 Submitted

updateios breaks the update due to network disruption

You can reach out Deepak Menezes(deepakme@in.ibm.com) .This is with respect to issue we hit on case TS011570960Was installing Fix Pack 3.1.4.10 on top of his system 3.1.3.14.During the installation the Putty session disconnected due to network dis...
12 months ago in PowerVM VIOS 0 Submitted

Correct error caused by Flash Copy -> VIOS_VFC_CLIENT_CON IDENTIFIER: B7BCD6A0 Description Virtual FC Client connection lost with I/O pending Probable Causes Client Timed out I/O or moved to another server during partition mobility

Please have the PowerHA Flash Copy Toolkit team look at correcting, possibly add additional delay time between the shutdown and power up of the flash copy partition to prevent locks, maybe they will see the issue in the code on their side
about 1 year ago in PowerVM VIOS 0 Submitted

Add LSO IPv6 SEA/VEA attributes to VIOS Performance Advisor and potentially default rules

The VIOS Performance Advisor is a very useful tool to verify the configuration of a running VIOS LPAR. Currently only some of the LargeSend attributes are reported when incorrectly set. Based on TS010353771, I was advised one of the IPv6 attribut...
over 1 year ago in PowerVM VIOS 0 Submitted

SEA over a 10Gb Ethernet Port in VIOS. Allow Virtual Ethernet Adapters in client partitions to run at 10Gb rather than a maximum of 1Gb.

Current limitation of Virtual Ethernet Adapters to run at 1Gb. If a 10Gb Ethernet port is set up as an SEA in VIOS, then client partitions using the bridge of virtual to physical are limited by the Virtual Ethernet Adapter maximum of 1Gb bandwidth...
over 1 year ago in PowerVM VIOS 0 Submitted