Skip to Main Content
IBM Power Ideas Portal


This portal is to open public enhancement requests against IBM Power Systems products, including IBM i. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Hardware Management Console

HMC Central Patch Management for AIX, PowerVM, Firmware and Microcode

HMC should have a Patch Management: Central Patch Management for AIX, PowerVM, Firmware and Microcode. IBM should provide a easy way for Patch Management. System Firmware and Adapter microcode report in one tool (something Microcode Discovery tool...
about 2 years ago in Hardware Management Console Planned for future release
132 VOTE

Provide sum of energy consumed and system temperature to HMC

Energy and environmental aspects are getting more and more into focus when discussing datacenter efficiency The Power High-End (in a minimum P10 and future and maybe P9 as well) systems should be enabled to expose temperature and energy charts th...
over 3 years ago in Hardware Management Console Future consideration

Different time zones for the HMC

Small manufacturing customers very often use onre single Power System for their ERP infrasturcure, but they may have several LPARs for their subsidaries in Asia, Europe and Americas. These regions have different time zones, but the HMC has only on...
7 months ago in Hardware Management Console Submitted

Add option in "installios" for VIOS maintenance boot

Booting to maintenance mode becomes critical in situations where the VIOS is unable to boot, and the process requires using an image from a NIM server or physical media which becomes an obstacle to recovery and often ends up reinstalling the VIOS ...
2 months ago in Hardware Management Console Submitted
145 VOTE

Dynamically editable min/max fields when LPAR gets shut down

When you are on a partitions memory configuration section and the partition is running you can only change the allocated value and the min/max values are greyed out. When the partition is then shut down the min/max values should be editable but th...
almost 5 years ago in Hardware Management Console Future consideration
124 VOTE

HMC Performance Dashboard shows different calculated graphs depending if the LPAR is in Shared-Pool and Dedicated Mode

At the moment the HMC Performance Dashboard is using a different calculation method - depending on the LPAR using Shared-Pool or Dedicated-Donating Mode - to display the CPU utilization graph without any hint of these differences. Both graphs are ...
over 4 years ago in Hardware Management Console Future consideration

Allow scheduled tasks in HMC schedule management to be edited

When you have created a scheduled Task like "backup profile data" or "backup HMC data" it os only possible to view or delete the Task. So if you want to Change the schedule to a new time oder date, you have to delete and receate the Task. It would...
8 months ago in Hardware Management Console Submitted

Perform integrity check of VIOS Fix Packs on install and/or transfer to HMC

During a recent VIOS update, we downloaded a fix pack ISO using Fix Central and transferred it to the HMC. Turns out that the ISO was partially corrupted.It was the correct size, and was mountable in various operating systems.However, many files w...
3 months ago in Hardware Management Console Planned for future release

Add Group-Tags in dynamic inventory in powervm_inventory

Hello, Grouptags are a cool feature in the HMC GUI. Unfortunately, they are no longer available via the CLI. -> https://ibm-power-systems.ideas.ibm.com/ideas/HMC-I-554 It would be great to have this feature in the dynamic HMC Ansible inventory ...
3 months ago in Hardware Management Console Planned for future release

Return previous functionality to virtual storage management via top level server to allow changes to client vFC and fcs ports.

If a VIOS fcs port fails or becomes unreliable there is no means to move the existing client vFC (WWPN) to a different fcs via the GUI. This capability was available in a previous release - along with the ability to create RO virtual media in the ...
6 months ago in Hardware Management Console Submitted