Skip to Main Content
IBM Power Ideas Portal


This portal is to open public enhancement requests against IBM Power Systems products, including IBM i. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

Status Not under consideration
Workspace IBM i
Categories Languages - RPG
Created by Guest
Created on Dec 30, 2025

Add configurable continuation start column (left margin) for fully free-form RPG (**FREE)

RPG IV currently supports two “free format” models:

Hybrid free format (traditional RPG IV), where a statement is considered free format when it begins in column 8 or later.

Fully free format using **FREE in column 1, where all source lines are free format and begin in column 1.

While these two models appear syntactically similar, they behave differently when handling continued literals or constants, particularly quoted strings. This difference creates subtle functional changes when migrating existing hybrid free-format RPG to fully free-format RPG.

In hybrid free format, continuation lines are interpreted starting either at:

  • First non-blank character (+ continuation),
  • Column 8 (- continuation).

When the same source is compiled under **FREE, continuation lines start in column 1, which can change the resulting value when continued literals use the minus symbol. And (sadly) I see a lot of RPG Developer's code where they aways use the - (minus) for continuation for some reason.

This behavior makes migrating existing hybrid RPG IV code (aka, /free RPG) to fully free format (**FREE) potentially risky and error-prone. Even when the source is visually identical, literal values can change due solely to differences in continuation column handling.

For large or mature RPG codebases, this complicates modernization efforts and undermines the goal of **FREE as a safe, incremental evolution of RPG syntax.

Requested Enhancement

Provide a way to configure the continuation start column (left margin) for continued source statements in fully free-format RPG.

Possible approaches include (examples only):

  • A compiler directive e.g., /LEFTMARGIN 8 (or similar)
  • An RPG Control (header) specification keyword. e.g., CTL-OPT MARGINS(8 : 80)

This setting would define the effective left margin for continuation lines, allowing developers to preserve existing continuation semantics when migrating from hybrid free format to fully free format (**FREE) RPG IV.

Idea priority Medium
  • Guest
    Jan 8, 2026
    Thank you for taking the time to submit your Idea. However, IBM does not intend to provide a solution to this Idea at this time, so it is being closed.

    When maintaining code with '-' continuation, it is already necessary to know whether the source begins with **FREE.

    If the meaning of a statement with '-' continuation might also depend on a CTL-OPT keyword or a directive, it would make the process of determining the meaning of the statement even more complex.

    Regarding conversion, tools doing the conversion have the option of changing the statement to have '+' continuation or even merging the two lines. If a person is doing manual conversion, they would have to know that there is an issue with '-' continuation, and in that case they can just make the necessary correction.