Skip to Main Content
IBM Power Ideas Portal


This portal is to open public enhancement requests against IBM Power Systems products, including IBM i. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

Status Delivered
Workspace PowerHA for AIX
Created by Guest
Created on Jul 31, 2017

Enhancing PowerHA cl_svc_info script and logic

This RFE is intended to help to solve an issue with clusterware software PowerHA 7.1.3.6 we face (but will hit 7.2 sure), namely "cl_svc_info" script (and maybe several others, older scripts) as that usually work based on checking svc/storage boxes exact IP addresses vs. storage box names etc., as well as various other checks etc.

We would appreciate to change that currently implemented clusterware scripts logic (or possibility to bring a workaround or fix by IBM) as those checks make no sense for us (in mean, for client, as client rely on datecenter storage replications functionality) in clustered environments. If any checks, then better would be check for example storage IDs itself (e.g.). The reason is that we are working in NATed environment and storage box IP published to all powerha clients is not necessary the same that is IP own to that particular storage box (with that name). We are talking here about V7K boxes.

IBM support says that we are currently not supported and is therefore invalid configurantion (see PMR 01498,999,693), however there is no restriction mentioned with regards of NAT at requirements for implementing Limitations and restrictions for PowerHA SystemMirror Enterprise Edition Metro Mirror for SVC, see: https://www.ibm.com/support/knowledgecenter/SSPHQG_7.1.0/com.ibm.powerha.pprc/ha_pprc_svc_limit.htm .

Verification

Idea priority Urgent
  • Guest
    Reply
    |
    Jun 25, 2019

    This functionality has been delivered with PowerHA 7.2.3. SP1.

    Once upgraded to PowerHA 7.2.3, the code will take care of the necessary migration steps and save the SVC ID in ODM.
    After that the ID is checked against the IP address and make sure the communication is continued.

    Please verify the changes.