Skip to Main Content
IBM Power Ideas Portal

Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Post your ideas

Start by posting ideas and requests to this portal to enhance a Power product or service. Take a look at ideas others have posted and upvote them if they matter to you,

  1. Post an idea

  2. Upvote ideas and add comments to ideas that matter most to you

  3. Get feedback from the IBM team to refine your idea

Help IBM prioritize your ideas and requests

The IBM team may need your help to refine the ideas so they may ask for more information or feedback. The Power teams will then decide if they can begin working on your idea. If they can start during the next development cycle, they will put the idea on the priority list. Each team at IBM works on a different schedule, where some ideas can be implemented right away, others may be placed on a different schedule.

Receive notification on the decision

Some ideas can be implemented at IBM, while others may not fit within the development plans for the product. In either case, the team will let you know as soon as possible. In some cases, we may be able to find alternatives for ideas which cannot be implemented in a reasonable time.


Specific link you will want to bookmark for future use

IBM Unified Ideas Portal - https://ideas.ibm.com/ - Use this site to create or search for existing Ideas across all IBM products that are outside of Power, and track all of your personal interactions with all Ideas.

Status Future consideration
Workspace PowerVM VIOS
Created by Guest
Created on Aug 18, 2020

LPM for LPARs with vNIC causes false call home

When LPM moving LPARs whith vNIC adapters to a different power server during the removal stage we see errlog entries in the hosting VIO server like:

Jun 19 08:50:29 ent16 T LNC2ENT_EEH_EXIT EEH recovery exit
Jun 19 08:50:28 sysplanar0 T PCI_RECOVERABLE_ERR Bus ID 9000038F EEH temporary error
Jun 19 08:50:28 ent16 T LNC2ENT_EEH_ENTRY EEH recovery entry
Jun 19 08:50:28 ent16 T LNC2ENT_HW_TMP_ERR Hardware temporary error
Jun 19 08:50:25 ent16 T LNC2ENT_HW_TMP_ERR Hardware temporary error
Jun 19 08:50:24 Migration I MVR_MIG_COMPLETED Migration completed successfully
Jun 19 08:50:24 ent16 T LNC2ENT_HW_TMP_ERR Hardware temporary error
Jun 19 08:50:23 ent16 T LNC2ENT_HW_TMP_ERR Hardware temporary error
Jun 19 08:50:22 ent16 T LNC2ENT_HW_TMP_ERR Hardware temporary error
Jun 19 08:50:22 ent16 T LNC2ENT_EEH_DETECT EEH freeze detected
Jun 19 08:50:22 vnicserver3 I VS_TRANSPORT_EVENT VNIC Transport Event
Jun 19 08:50:21 Migration I MVR_PHYP_SUSPEND Client partition suspend issued

These EEH errors are a part of the vnic removal / failover process and therefore are expected and do not log real errors that need attention.
Call home function reports these errors and therefore causes false events / actions for IBM support and AIX administrators.

This can not be corrected in scope of PMR.

Submitted case for that problem - TS003789179

Idea priority High
  • Guest
    Aug 19, 2020

    IBM is exploring improvements with the error management of different VNIC related adapters