Skip to Main Content
IBM Power Ideas Portal


This portal is to open public enhancement requests against IBM Power Systems products, including IBM i. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Hardware Management Console

Showing 167
143 VOTE

Dynamically editable min/max fields when LPAR gets shut down

When you are on a partitions memory configuration section and the partition is running you can only change the allocated value and the min/max values are greyed out. When the partition is then shut down the min/max values should be editable but th...
over 3 years ago in Hardware Management Console 3 Future consideration
128 VOTE

Provide sum of energy consumed and system temperature to HMC

Energy and environmental aspects are getting more and more into focus when discussing datacenter efficiency The Power High-End (in a minimum P10 and future and maybe P9 as well) systems should be enabled to expose temperature and energy charts th...
almost 2 years ago in Hardware Management Console 1 Future consideration
123 VOTE

HMC Performance Dashboard shows different calculated graphs depending if the LPAR is in Shared-Pool and Dedicated Mode

At the moment the HMC Performance Dashboard is using a different calculation method - depending on the LPAR using Shared-Pool or Dedicated-Donating Mode - to display the CPU utilization graph without any hint of these differences. Both graphs are ...
almost 3 years ago in Hardware Management Console 2 Future consideration

Call Home test for vHMC

At the moment there is no way to check, if vHMC Call Home configuration is working properly.As verified by IBM Support Case neither "Test connection" during configuration wizard nor "Creating a serviceable event" with checked flag "Test problem re...
over 3 years ago in Hardware Management Console 1 Future consideration

Awarness of multiple HMC's in the GUI (arbitration)

There is currently no ability to see the HMC arbitration status in the GUI. When deploying redundant HMC's that manages the same system(s) it would be good to see the status of both the primary and secondary HMC in terms of their role so the user ...
over 3 years ago in Hardware Management Console 2 Future consideration

User friendly logging of any change activity on HMC for LPAR and Power Server itself

Would like to have a recording of activities like change,add,remove things for LPAR and/or Power Server in the HMC. The task window is not enough and shows only minimal change information.
about 3 years ago in Hardware Management Console 0 Future consideration

HMC nmon

HMC nmon implementation or enhancement of monhmc
over 2 years ago in Hardware Management Console 0 Future consideration

physical port on destination side for the migrating client LPAR

Physical port (FCS)on destination side for the migrating client LPAR can not see during the LPM on HMC GUI , so as mentioned the option is only available from HMC CLI with the command below: ~> migrlpar -o v -m <source_managed_system> -t ...
about 3 years ago in Hardware Management Console 1 Future consideration

Instantaneous consumption of IBM Power servers

With the great challenges of energy reduction that we will have to face and in the perspective of "greenIT", it would be interesting to me to be able to know the instantaneous consumption of the Power (and others) infrastructure . As requested by ...
about 2 years ago in Hardware Management Console 2 Future consideration

HMC GUI - choose specific FC adapter on target VIOS

A customer has multiple Fibre Channel connections to SAN Fabric A on VIOS#1 and VIOS#2 has multiple connections to SAN Fabric B. Using the command line migrlpar it is possible to specify the target VIOS and specific FC adapter port. Can the HMC GU...
over 3 years ago in Hardware Management Console 1 Future consideration