Skip to Main Content
IBM Power Ideas Portal
Hide about this portal


This portal is to open public enhancement requests against IBM Power Systems products, including IBM i. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Hardware Management Console

Showing 387

Add advanced vNIC to HMC Collection

If you have a trunked VLAN on the network side, set the VLAN as PortVLANID. This is used very often. Unfortunately, there is no option to do this with Ansible in the HMC-collection. i create also a git issue https://github.com/IBM/ansible-power-hm...
about 1 month ago in Hardware Management Console 1 Planned for future release

Allow Simplified HMC based Remote Restart to recreate LPAR on target system even with reduced paths to the LUN

Simplified HMC based Remote Restart is currently not successful if the check on the target system results in a reduced number of paths to the LUN. This is the case with a HyperSwap configuration in the event of a data center failure (storage and s...
8 months ago in Hardware Management Console 1 Planned for future release

Resource role permissions should be transfered to new system during LPM

Current situation: When permission to a specific LPAR is defined in a given resource role, permission is automatically given to the hosting server. If the LPAR is migrated to another hosting server, permission to this new server is not given autom...
9 days ago in Hardware Management Console 0 Submitted

We request that the System Location field be queryable from the HMC command line, similar to other fields.

In the HMC GUI, if you navigate to System Resources, then Systems, and finally System Settings, you will find fields labeled "System Location" and "Description." These fields allow for free-form text entry. Would like the ability to query these fi...
16 days ago in Hardware Management Console 2 Planned for future release

Create CLI command that shows the same Virtual fiber data as displayed in HMC GUI.

Currently when logged into V10 HMC code gui when you select an lpar -> select adapter view then the virtual fiberchannel adapter tab it shows a table with the following details: Virtual IO server, client server adapter, location and the pair of...
9 days ago in Hardware Management Console 0 Submitted

HMC pedbg command single frame info

Currently the pedbg command grabs ALL relevant data from ALL the HMC's Managed Systems. This can take upwards of an hour especially when we're only interested in a single Managed System. We're requesting the pedbg command to have a switch to allow...
9 days ago in Hardware Management Console 0 Submitted
143 VOTE

Dynamically editable min/max fields when LPAR gets shut down

When you are on a partitions memory configuration section and the partition is running you can only change the allocated value and the min/max values are greyed out. When the partition is then shut down the min/max values should be editable but th...
over 3 years ago in Hardware Management Console 3 Future consideration
124 VOTE

HMC Performance Dashboard shows different calculated graphs depending if the LPAR is in Shared-Pool and Dedicated Mode

At the moment the HMC Performance Dashboard is using a different calculation method - depending on the LPAR using Shared-Pool or Dedicated-Donating Mode - to display the CPU utilization graph without any hint of these differences. Both graphs are ...
over 3 years ago in Hardware Management Console 2 Future consideration

centralized I/O Code Repository similar to the HMC repository for system firmware is required.

For system firmware, I can download the firmware via the internet to the local HMC repository once and use it for further system updates of other systems. This way, I always have the latest firmware available. With I/O, I don’t have this option. L...
3 months ago in Hardware Management Console 0 Submitted

HMC should work as ntp server for eBMC ntp clients

As Pete Heyrman documented: The enterprise baseboard management controller (eBMC) was introduced in Power10 and provides similar system management functionality as the FSP. With respect to time, the eBMC time-of-day clock cannot be synced with the...
about 1 year ago in Hardware Management Console 2 Planned for future release