IBM Power Ideas Portal

Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Post your ideas

Start by posting ideas and requests to this portal to enhance a Power product or service. Take a look at ideas others have posted and upvote them if they matter to you,

  1. Post an idea

  2. Upvote ideas and add comments to ideas that matter most to you

  3. Get feedback from the IBM team to refine your idea

Help IBM prioritize your ideas and requests

The IBM team may need your help to refine the ideas so they may ask for more information or feedback. The Power teams will then decide if they can begin working on your idea. If they can start during the next development cycle, they will put the idea on the priority list. Each team at IBM works on a different schedule, where some ideas can be implemented right away, others may be placed on a different schedule.

Receive notification on the decision

Some ideas can be implemented at IBM, while others may not fit within the development plans for the product. In either case, the team will let you know as soon as possible. In some cases, we may be able to find alternatives for ideas which cannot be implemented in a reasonable time.


Specific link you will want to bookmark for future use

IBM Unified Ideas Portal - https://ideas.ibm.com/ - Use this site to create or search for existing Ideas across all IBM products that are outside of Power, and track all of your personal interactions with all Ideas.

ADD A NEW IDEA

FILTER BY CATEGORY

PowerVM VIOS

Showing 73 of 3530

Need a permanent fix for the issues getting created by the presence of unused adapters in the System

We were told through case TS002396037 that the presence of unused Ethernet and Fiber Channel adapters are the cause for reoccurring SEA failures on our VIOs. Upon Failure we have to restart our VIOs to bring back the SEA to a stable state. We were...
about 3 years ago in PowerVM VIOS 0 Future consideration

support multibos under VIO

Support of multibos under VIO.
almost 5 years ago in PowerVM VIOS 2 Not under consideration

VIOS support for NPIV tape failover

There is no VIOS support for NPIV tape failover due to the fact that the tape devices have no "I/O re-try" option. If VIOSA fails, all virtual tape drives have to be reconfigured and re-mapped manually in VIOSn, or pre-configured using different W...
about 5 years ago in PowerVM VIOS 1 Not under consideration

PowerVM Shared Storage Pool support for Hitachi GAD devices

Customer is moving to a module concept for datacentre and want to user PowerVC to manage without access to Switches and SAN - Shared storage pools is the perfect solution, but needs to be able to support the Hitachi GAD concept (Hyperswap) with LU...
about 5 years ago in PowerVM VIOS 2 Not under consideration

LPM network interface option

During initial LPM (Powervm 2.2.5.10) The 'mover' presents several network interfaces to choose from. These interfaces have been test with a PING, (tested by LPM not user ) and PING have tested as affirmative. LPM assumes that network interface is...
about 5 years ago in PowerVM VIOS 1 Future consideration

Add Network Tunnelling support via VXLAN or GRE for PowerVM

PowerVM lacks of support for SDN solutions and only supports legacy vlan based layer 2 networks.Against this hypervisors under x86 supports network tunnelling technology. For example KVM supports VXLAN or GRE using OpenvSwitch. ESX supports VXLAN ...
almost 7 years ago in PowerVM VIOS 2 Future consideration

Provide ability for virtual optical devices larger than 4.3GB

Using Virtual Media Library the optical device is restricted to 4.3GB in size. It then prompts for a second volume for images larger than 4.3GB.Requesting possibility to have virtual optical device increased beyond 4.3GB
about 7 years ago in PowerVM VIOS 2 Not under consideration

PowerVM Shared storage pool cluster

Current limitation of number of nodes in a Shared Storage pool cluster is too small. Need to expand the cluster to support up to 32 nodes (8 Servers in Primary and 8 in secondary - each with 2 VIO Servers).Else can we install GPFS and build a GPFS...
about 5 years ago in PowerVM VIOS 2 Not under consideration

Concurrent SR-IOV Migration

LPM of LPARs from Servers with Shared Ethernet Adapters (SEA) to Servers using vNIC and SR-IOV adapters is not possible directly. Hence the migration requires new definition of Ethernet-communication in target LPAR, which requires an outage of the...
about 5 years ago in PowerVM VIOS 1 Not under consideration

SSP LUN Space Reclaim

When using SSP deployment, Tiers can be created as Thin provisioned thus consuming LUN space that is used in the assigned LPARs.By time data in the LUs is written and subsequently erased, causing the LUs (and their containing tiers) to inflate.The...
almost 3 years ago in PowerVM VIOS 1 Not under consideration