Skip to Main Content
IBM Power Ideas Portal


This portal is to open public enhancement requests against IBM Power Systems products, including IBM i. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

PowerVM VIOS

Showing 94 of 4545

Better troubleshooting when HMC doesn't display devices like disks when it should.

When the CMDB on the VIOS server is wrong, then the HMC simply does not display what you should see, and you have zero insight into why. We had issues with disks, missing UUIDs, or other errors. There should be a command, maybe a little more refin...
over 2 years ago in PowerVM VIOS 0 Planned for future release

Code enhancement to handle VIOS Path loss issues during Brocade haReboot - There have been multiple outages experienced in IBM VIO Server(VIOS) managed environment, during storage related events. The haReboot performed on Brocade SAN switches are supposed to be non-disruptive, but in reality they do take a finite amount of time. In VIO managed environments, this has sometimes resulted in impact and affected availability. During a haReboot the fabric services are not available and hence when the VIOS queries the Name server on the switch, it may not get the desired response due to the haReboot in progress. This results in the VIOS logging out and attempting to log back in again, resulting in path failures at the VIOS. To prevent the same from happening, the VIOS code can be updated to include an appropriate time interval that kicks in as and when the haReboot is in progress. The VIOS will then wait for this interval and pause any activity, before querying the name server again. The assumption is that the haReboot RSCN notification is sent correctly by the Brocade switches and received by the VIO servers. If not, then this can be worked out jointly by Brocade and IBM, to prevent outages in the future. The referenced Support Case has additional information.

among all the different vendor servers, the IBM VIOS managed AIX server environments seem to be susceptible and have experienced outages as and when haReboot is performed.
over 2 years ago in PowerVM VIOS 1 Not under consideration

viosecure -level high should set default firewall rules to denied for inbound traffic

IBM support case TS006803177:---------------------------------------After applying vioscure level 'high', the default firewall rule 0 permits all IP packages, if an IP package does not met any rules. This make the firewall settings useless if you ...
over 3 years ago in PowerVM VIOS 1 Future consideration

PowerVM language/locale selection

While running PowerVM update, there are installed ~700 filesets related to regional messages/translations. This is prolonging install time and increasing used space.
almost 4 years ago in PowerVM VIOS 0 Planned for future release

Auto pick Fiber Adapter in VIOS

VMware- ESX server which automatically re-maps the virtual client adapters to different physical adapters when physical adapters have issues. This will help in automatically correct path problems on LPARs As of now, VIO does not have any such feat...
over 4 years ago in PowerVM VIOS 0 Future consideration

Add Ethernet adapter e4148a1614109304 to AIX ARTEX catalog (for use with VIOS rules)

See IBM Support Case Number TS003577743 Unable to add VIOS rules for adapterPCIe2 4-Port Adapter (10GbE SFP+) (e4148a1614109304) lsdev -F "name:class/subclass/type" -l ent0ent0:adapter/pciex/e41457162004000 $ rules -o add -t adapter/pciex/e4145716...
almost 5 years ago in PowerVM VIOS 0 Future consideration

VIOS storage mirror testing over distant datacenters

To increase the rubustness of the VIOS, it is highly appreciated to also do testing for storage mirroring over distant datacenters.The requesting client has an environment of about 5.000 vscsi disks from two datacenters with a distance of 5 miles....
over 5 years ago in PowerVM VIOS 0 Not under consideration

Padmin GID Non-0

Change padmin group to non-zero We have manually set many of our VIOS instances to 1 staff without any issues. However this is non-standard and not supported by IBM. Need a supported option from IBM. RFQ system doesn't allow Salesforce cases. TS00...
over 5 years ago in PowerVM VIOS 2 Not under consideration

PowerVM Shared storage pool cluster

Current limitation of number of nodes in a Shared Storage pool cluster is too small. Need to expand the cluster to support up to 32 nodes (8 Servers in Primary and 8 in secondary - each with 2 VIO Servers).Else can we install GPFS and build a GPFS...
over 7 years ago in PowerVM VIOS 2 Not under consideration

Concurrent SR-IOV Migration

LPM of LPARs from Servers with Shared Ethernet Adapters (SEA) to Servers using vNIC and SR-IOV adapters is not possible directly. Hence the migration requires new definition of Ethernet-communication in target LPAR, which requires an outage of the...
over 7 years ago in PowerVM VIOS 1 Not under consideration