Skip to Main Content
IBM Power Ideas Portal


This portal is to open public enhancement requests against IBM Power Systems products, including IBM i. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

PowerVM VIOS

Showing 89 of 4276

PowerVM Shared storage pool cluster

Current limitation of number of nodes in a Shared Storage pool cluster is too small. Need to expand the cluster to support up to 32 nodes (8 Servers in Primary and 8 in secondary - each with 2 VIO Servers).Else can we install GPFS and build a GPFS...
almost 7 years ago in PowerVM VIOS 2 Not under consideration

PowerVM Shared Storage Pool support for Hitachi GAD devices

Customer is moving to a module concept for datacentre and want to user PowerVC to manage without access to Switches and SAN - Shared storage pools is the perfect solution, but needs to be able to support the Hitachi GAD concept (Hyperswap) with LU...
almost 7 years ago in PowerVM VIOS 2 Not under consideration

LPM network interface option

During initial LPM (Powervm 2.2.5.10) The 'mover' presents several network interfaces to choose from. These interfaces have been test with a PING, (tested by LPM not user ) and PING have tested as affirmative. LPM assumes that network interface is...
almost 7 years ago in PowerVM VIOS 1 Future consideration

Concurrent SR-IOV Migration

LPM of LPARs from Servers with Shared Ethernet Adapters (SEA) to Servers using vNIC and SR-IOV adapters is not possible directly. Hence the migration requires new definition of Ethernet-communication in target LPAR, which requires an outage of the...
almost 7 years ago in PowerVM VIOS 1 Not under consideration

Enhancement Requested for Shared Storage Pools (SSPs)

Customer asked for an "automated way" to avoid having to manually map all of the shared storage pools (SSPs) created on production system (in Mississippi) to disaster recovery/HA system (in Arizona). Would like script or other utility provided wit...
almost 7 years ago in PowerVM VIOS 2 Not under consideration

Enhance VIOS "Virtual SCSI Optical/ISO images" --- to mirror VMware ESXi functionality for "Virtual SCSI Optical/ISO images"

Enhance VIOS "Virtual SCSI Optical/ISO images" --- to mirror VMware ESXi functionality for "Virtual SCSI Optical/ISO images" #####################################mkrep -sp rootvg -size 20Gls -l /fix/AIX_v7.2_Base_Install_DVD_1_of_2_TL_7200-01-01.1...
about 7 years ago in PowerVM VIOS 3 Not under consideration

rmvdev -rmlv should check to see if LV is in use before removing

To avoid deleting an active/used LV, it would be really helpful if the 'rmvdev' (and any other commands that remove LVs from the VIO Server) would check to see if a specified LV is stil in use or not.
about 7 years ago in PowerVM VIOS 1 Not under consideration

Automatic Port Speed Synchronization for NPIV vFC Client Adapter

Changes to the port speed attribute of a physical FC adapter in the VIOS are not automatically passed along to the NPIV vFC adapters in the client LPARs. NPIV vFC adapters need be reconfigured to learn about the new port speed setting of the under...
over 7 years ago in PowerVM VIOS 1 Not under consideration

Vios - enhance lsnports command to provide more info

Enhance the command lsnports so that it displays additional info that what is shows already I would like to be able to see Customer Added info (From the odm) added by maybe a chdev to add a description field for each lsnports entry to show me (fab...
over 7 years ago in PowerVM VIOS 2 Not under consideration

Dual VIOS env.: vhost-to-slot ID combination after LPM operation must be equal on both target VIOS

We use LPARS with DualVIO on Power Systems. We need to track Diskmappings to Hosts in Dokumentation, also need to add an delete disk mappings als Virtual Target Device on VIO for the LPAR.At start we get 3 vhosts per LPAR in ascending order, the o...
almost 8 years ago in PowerVM VIOS 4 Not under consideration